.: Technical Data for EHID Ballasts
Updated: 29 July, 2010
.: Technical Information
Physical Data:
![]() |
Electrical Data:: Input: DC 198V-254V Output: |
Technical
Features:
Smart ignition regime - computed ignition attempts and shutdown are implemented according to actual conditions
Innovative design allows for exceptionally lowballast losses
Same ballast can operate all types of HIDlamps: MH (quartz &ceramic), HPS and Mercury lamps
Lamp operates at low frequency square wave(83Hz):
- Prevents acoustic resonance
- Flicker free
-Improved lamp longevity and lumen maintenance
-Prevents partial glow discharge in the lamp and high leading voltage peaks
Broad operating temperature range: -20ºC< Ta < +50ºC
Power Factor > 0.98, registered patents for active power factor correction
Negligible inrush current on activation (prevents fuse/CB tripping)
Complete digital control achieved by a single state-of-the-art microprocessor allowing for:
- Fewer control components
- Greater flexibilityinqualitycontrolformulas
- Greater control over data and program variables
- Easily upgradable programs
- Lower power losses in comparison with other brands of ballasts with square wave lamp current operation.
- Prevents acoustic resonance
- Flicker free
-Improved lamp longevity and lumen maintenance
-Prevents partial glow discharge in the lamp and high leading voltage peaks
- Fewer control components
- Greater flexibilityinqualitycontrolformulas
- Greater control over data and program variables
- Easily upgradable programs
- Lower power losses in comparison with other brands of ballasts with square wave lamp current operation.
Safety Features:
Internal temperature control protects the ballast
- Output power reduction when internal temperature rises above85°C
- Shutdown when internal temperature rises above 90°C (4restarts after cooling)
Protection against lamp faults (EOL): DC condition,(rectification),cycling,ignitionfailure,NoLoad protection,short-circuit at lamp terminals, external arc, high/low lamp voltage. (Shutdown can be reset)
Protection at abnormal mains conditions:
over-voltage, under-voltage and network interference(EN61547)
- Output power reduction when internal temperature rises above85°C
- Shutdown when internal temperature rises above 90°C (4restarts after cooling)
over-voltage, under-voltage and network interference(EN61547)
Controlling and Monitoring:
Internal data accumulation and external communication facilitate real-time monitoring and/or periodical analysis and diagnosis
Lamp monitoring: end of life, defective lamp, etc.
Various communication protocols (input from control device) DALI & PWM
Automatic dimming can be set to respond to a programmable schedule (multiplex scenes) or variable conditions, such as occupancy and daylight harvesting